Adjusting Setpoint <1>
n Push the <SP> button with a pin (max. ø1.1 mm). The
gauge changes to the switching function mode and outputs
the current lower threshold value at the measurement
value output for about 10 s (LED <1> flashes).
Press the button
max. ø1.1 mm
o For changing the threshold value, push the <ZERO> button
and keep it depressed. The threshold keeps changing from
the current value (ramp) until the button is released or until
the limit of the setting range is reached.
max. ø1.1 mm
Keep the button depressed